Prepared and frozen foods plants make some of the toughest wastewater in the food industry. Cooking oils, sauces, starches and proteins end up in the drain together with CIP chemicals and washdown water, and the result can swing from acidic to alkaline within a single shift.
A specialty prepared foods manufacturer faced exactly that: fats, oils and grease averaging around 700 mg/L, TSS around 1,400 mg/L and high BOD and COD, at 50 to 150 GPM with peaks near 200 GPM. The plant needed to meet municipal sewer limits and cut its surcharges.
Pan America Environmental built a pretreatment train around three stages. A GTI-1650 grease interceptor, held at about 125°F so the grease stays liquid, removes free FOG and coarse solids first. An equalization tank then feeds a steady flow to a ChemClear CT two-stage chemical treatment system, with chemistry set by jar testing, and a PD-50 plate DAF floats out what remains. Intell-i-Touch controls run and monitor the whole system.
Typical results after optimization are 90–95%+ FOG removal and 90–97% TSS removal, with pH neutralized to 6.5–8.5 before discharge. The recovered FOG is even hauled by secondary-market vendors, helping the owner recoup costs.